Staphylococcus Aureus sareng Staphylococcus Aureus Tahan Methicillin (MRSA/SA)
Ngaran Produk
HWTS-OT062 Staphylococcus Aureus sareng Methicillin-Resistant Staphylococcus Aureus (MRSA/SA) Kit Deteksi Asam Nukléat (Fluoresensi PCR)
Sertipikat
CE
Épidemiologi
Staphylococcus aureus mangrupakeun salah sahiji baktéri patogén penting inféksi nosocomial.Staphylococcus aureus (SA) kagolong kana staphylococcus sareng mangrupikeun wawakil baktéri Gram-positip, anu tiasa ngahasilkeun rupa-rupa racun sareng énzim invasif.Baktéri ngagaduhan ciri distribusi anu lega, patogénitas anu kuat sareng tingkat résistansi anu luhur.Gén nukléase termostabil (nuc) nyaéta gén staphylococcus aureus anu dijaga pisan.
Saluran
FAM | gén mecA tahan methicillin |
ROX | Kontrol internal |
CY5 | gén nuc staphylococcus aureus |
Parameter Téknis
Panyimpenan | ≤-18 ℃ & ditangtayungan tina cahaya |
Kahirupan rak | 12 bulan |
Jenis spésimén | sputum, sampel inféksi kulit jeung jaringan lemes, sarta sampel swab nasal |
Ct | ≤36 |
CV | ≤5,0% |
LoD | 1000 CFU/mL staphylococcus aureus, 1000 CFU/mL baktéri tahan methicillin.Nalika kit ngadeteksi rujukan LoD nasional, 1000/mL staphylococcus aureus tiasa dideteksi |
Spésifikasi | Uji réaktivitas silang nunjukkeun yén kit ieu henteu gaduh réaktivitas silang sareng patogén pernapasan sanés sapertos staphylococcus aureus anu sénsitip methicillin, staphylococcus coagulase-négatip, staphylococcus epidermidis anu tahan methicillin, pseudomonas aeruginosa, escherichia coli, klebsiumaniellabacter mirabilis, enterobacter cloacae, streptococcus pneumoniae, enterococcus faecium, candida albicans, legionella pneumophila, candida parapsilosis, moraxella catarrhalis, neisseria meningitidis, haemophilus influenzae. |
Instrumén lumaku | Applied Biosystems 7500 Real-Time PCR Systems QuantStudio®5 Sistem PCR Real-Time SLAN-96P Real-Time PCR Systems LightCycler®480 Sistim PCR Real-Time LineGene 9600 Ditambah Real-Time Sistim deteksi PCR MA-6000 Real-Time kuantitatif termal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time Sistim PCR |
Aliran Gawé
Pilihan 1.
Macro & Micro-Test Genomic DNA/RNA Kit (HWTS-3019) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. tiasa dianggo sareng Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS- 3006B).Tambahkeun 200µL saline normal kana endapan anu diolah, sareng léngkah-léngkah saterasna kedah diekstrak dumasar kana petunjuk, sareng volume élusi anu disarankeun nyaéta 80µL.
Pilihan 2.
Macro & Micro-Test Sample Reagent Reagen (HWTS-3005-8) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Tambahkeun 1mL saline normal ka endapanana sanggeus dikumbah ku saline normal, teras gaul ogé.Centrifuge dina 13.000r/mnt salila 5 menit, piceun supernatant (cadangan 10-20μL supernatant), tur turutan parentah pikeun ékstraksi saterusna.
Réagen ékstraksi anu disarankeun: Ekstraksi Asam Nukléat atanapi Réagen Pemurnian (YDP302) ku Tiangen Biotech (Beijing) Co.,Ltd.Ékstraksi kudu dilaksanakeun sacara ketat dumasar kana léngkah 2 tina manual instruksi.Disarankeun ngagunakeun RNase sareng cai bébas DNase pikeun élusi kalayan volume 100µL.