SARS-CoV-2/influenza A/influenza B
Ngaran Produk
HWTS-RT148-SARS-CoV-2/influenza A /influenza B Kit Detéksi Gabungan Asam Nukléat (Fluoresensi PCR)
Saluran
Ngaran Saluran | PCR-Campuran 1 | PCR-Mix 2 |
Saluran FAM | gén ORF1ab | IVA |
Saluran VIC/HEX | Kadali internal | Kadali internal |
Saluran CY5 | N gén | / |
Saluran ROX | E gén | IVB |
Parameter Téknis
Panyimpenan | -18 ℃ |
Kahirupan rak | 12 bulan |
Jenis spésimén | swab nasopharyngeal jeung swab oropharyngeal |
Sasaran | SARS-CoV-2 tilu target (Orf1ab, N jeung E gén)/influenza A / influenza B |
Ct | ≤38 |
CV | ≤10,0% |
LoD | SARS-CoV-2: 300 Salinan/mL virus influenza A: 500 Salinan/mL virus influenza B: 500 Salinan/mL |
Spésifikasi | a) Hasil tés silang nunjukkeun yén kit éta cocog sareng coronavirus manusa SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, virus respiratory syncytial A sareng B, virus parainfluenza 1, 2 sareng 3, rhinovirusA, B sareng C, adenovirus 1, 2, 3, 4, 5, 7 sareng 55, metapneumovirus manusa, enterovirus A, B, C sareng D, virus pulmonal sitoplasma manusa, virus EB, virus cacar Sitomegalovirus manusa, rotavirus, norovirus, virus mumps, virus varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergi no glaucoma, Candidallus glauces réaksi silang antara Pneumocystis yersini jeung Cryptococcus neoformans. b) Kamampuhan anti gangguan: pilih mucin (60mg/mL), 10% (V/V) getih manusa, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), natrium klorida (ngandung pengawet) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisone (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamin hidroklorida (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL). ), ritonavir (60mg/mL), mupirocin (20mg/mL), azitromisin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) jeung tobramycin (0.6mg/mL) .Hasilna nunjukkeun yén zat anu ngaganggu dina konsentrasi di luhur henteu gaduh réspon gangguan kana hasil deteksi patogén. |
Instrumén lumaku | Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 gancang Real-Time PCR Systems SLAN ®-96P Real-Time PCR Systems QuantStudio™ 5 Sistem PCR Real-Time LightCycler®480 Sistim PCR Real-Time LineGene 9600 Ditambah Real-Time Sistim deteksi PCR MA-6000 Real-Time kuantitatif termal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time Sistim PCR |