SARS-CoV-2/influenza A/influenza B
Ngaran produk
Pakakas Detéksi Gabungan Asam Nukléat HWTS-RT148-SARS-CoV-2/influenza A/influenza B (PCR Fluoresensi)
Saluran
| Ngaran Saluran | Campuran PCR 1 | Campuran PCR 2 |
| Saluran FAM | Gén ORF1ab | IVA |
| Saluran VIC/HEX | Kontrol internal | Kontrol internal |
| Saluran CY5 | Gén N | / |
| Saluran ROX | Gén E | IVB |
Parameter Téknis
| Panyimpenan | -18℃ |
| Umur simpan | 12 bulan |
| Jenis Spésimen | usap nasofaring sareng usap orofaring |
| Sasaran | SARS-CoV-2 tilu target (gén Orf1ab, N sareng E)/influenza A /influenza B |
| Ct | ≤38 |
| CV | ≤10.0% |
| LoD | SARS-CoV-2:300 Salinan/mL Virus influenza A:500 Salinan/mL Virus influenza B:500 Salinan/mL |
| Spésifikasi | a) Hasil uji silang nunjukkeun yén kit ieu cocog sareng coronavirus manusa SARSr-CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, virus respiratory syncytial A sareng B, virus parainfluenza 1, 2 sareng 3, rhinovirusA, B sareng C, adenovirus 1, 2, 3, 4, 5, 7 sareng 55, metapneumovirus manusa, enterovirus A, B, C sareng D, virus pulmonal sitoplasma manusa, virus EB, virus campak Sitomegalovirus manusa, rotavirus, norovirus, virus gondongan, virus varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertusis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergillus fumigatus, Candida albicans, Candida glabrata Teu aya réaksi silang antara Pneumocystis yersini sareng Cryptococcus neoformans. b) Kamampuh anti gangguan: pilih musin (60mg/mL), 10% (V/V) getih manusa, difenilefrin (2mg/mL), hidroksimetilzolin (2mg/mL), natrium klorida (ngandung pengawet) (20mg/mL), beklometason (20mg/mL), deksametason (20mg/mL), flunison (20μg/mL), triamsinolon asetonida (2mg/mL), budesonida (2mg/mL), mometason (2mg/mL), flutikason (2mg/mL), histamin hidroklorida (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) sareng tobramycin (0.6mg/mL). Hasilna nunjukkeun yén zat anu ngaganggu dina konsentrasi di luhur teu ngagaduhan réspon gangguan kana hasil deteksi patogén. |
| Instrumen anu Lumaku | Sistem PCR Real-Time Biosystems Terapan 7500 Sistem PCR Real-Time Gancang Biosystems Terapan 7500 SLAN ®Sistem PCR Real-Time -96P Sistem PCR Real-Time QuantStudio™ 5 LightCycler®480 Sistem PCR Real-Time Sistem Deteksi PCR Real-Time LineGene 9600 Plus Siklus Termal Kuantitatif Waktos Nyata MA-6000 Sistem PCR BioRad CFX96 Real-Time Sistem PCR Real-Time BioRad CFX Opus 96 |
Larutan PCR Total