Patogén engapan Gabungan
Patogén Pernafasan Gabungan Rincian:
Ngaran produk
HWTS-RT050-Genep Jenis Kit Deteksi Asam Nukléat Patogén Pernapasan(Fluoresensi PCR)
Épidemiologi
Influenza, ilahar disebut 'flu', nyaéta kasakit tepa saluran pernapasan akut disababkeun ku virus influenza, nu kacida tepa sarta utamana dikirimkeun ku batuk jeung bersin.
Respiratory syncytial virus (RSV) nyaéta virus RNA, milik kulawarga paramyxoviridae.
Human adenovirus (HAdV) nyaéta virus DNA untai ganda tanpa amplop. Sahenteuna 90 genotip parantos kapendak, anu tiasa dibagi kana 7 subgenera AG.
Human Rhinovirus (HRV) mangrupa anggota kulawarga Picornaviridae jeung genus Enterovirus.
Mycoplasma pneumoniae (MP) nyaéta mikroorganisme patogén anu ukuranana antara baktéri sareng virus.
Saluran
| Saluran | PCR-campuran A | PCR-Campuran B |
| Saluran FAM | IFV A | HAdV |
| Saluran VIC/HEX | HRV | IFV B |
| Saluran CY5 | RSV | MP |
| Saluran ROX | Kontrol internal | Kontrol internal |
Parameter Téknis
| Panyimpenan | -18 ℃ |
| Kahirupan rak | 12 bulan |
| Jenis spésimén | Oropharyngeal swab |
| Ct | ≤35 |
| LoD | 500 Salinan/mL |
| Spésifikasi | 1.Hasil uji réaktivitas silang nunjukkeun yén teu aya réaksi silang antara kit sareng coronavirus manusa SARSr-CoV, MERSr-CoV, HCoV-OC43, HCoV-229E, HCoV-HKU1, HCoV-NL63, virus Parainfluenza jinis 1, 2, sareng 3, Chlamydia, Pneumoniae, B, Enterovirus, Pneumonia, B, Enterovirus. Virus Epstein-Barr, Virus Campak, Sitomegalovirus manusa, Rotavirus, Norovirus, Virus Mumps, Virus Varicella-zoster, Legionella, Bordetella pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycoballous tuberculosis, Aphrodite. albicans, Candida glabrata, Pneumocystis jiroveci, Cryptococcus neoformans jeung asam nukléat génomik manusa. 2.Kamampuhan anti gangguan: Mucin (60mg/mL), 10% (v/v) getih manusa, phenylephrine (2mg/mL), oxymetazoline (2mg/mL), natrium klorida (kalawan pengawet) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), dexamethasone (20mg/mL). acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), Fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), alpha-interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), ribavirin (10mg/mL) lopinavir (500mg/mL), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), cefprozil (40μg/mL), Meropenem (200mg/mL), levofloxacin (10μg/mL), jeung tobramycin nu dipilih pikeun interferensi (0. zat ngaganggu dina konsentrasi luhur teu boga réaksi interferensi kana hasil tés patogén. |
| Instrumén lumaku | Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 gancang Real-Time PCR Systems QuantStudio®5 Sistem PCR Real-Time SLAN-96P Real-Time PCR Systems LightCycler®480 Sistim PCR Real-Time LineGene 9600 Ditambah Real-Time Sistim deteksi PCR MA-6000 Real-Time kuantitatif termal Cycler BioRad CFX96 Real-Time PCR System, BioRad CFX Opus 96 Real-Time PCR System |
Solusi PCR total
Gambar detil produk:
Pituduh Produk Patali:
Ikhlas, Inovasi, Kakuatan, sareng Efisiensi mangrupikeun konsepsi pengkuh perusahaan kami pikeun jangka panjang pikeun ngembangkeun babarengan sareng para nasabah pikeun silih timbal balik sareng silih kauntungan pikeun Gabungan Patogén Pernafasan, Produk bakal nyayogikeun ka sakumna dunya, sapertos: Bélgia, Inggris, Walanda, Sadaya produk kami diékspor ka klien di Inggris, Jérman, Perancis, Spanyol, sareng Afrika Tengah. produk urang anu ogé tampi ku konsumén urang pikeun kualitas luhur, harga kalapa jeung gaya paling nguntungkeun. Urang ngaharepkeun pikeun ngadegkeun hubungan bisnis jeung sakabeh konsumén jeung mawa warna leuwih beautifu pikeun kahirupan.
Pausahaan sasuai jeung kontrak ketat, a pabrik pisan reputable, pantes kerjasama jangka panjang.


