12 Jenis Patogen Pernapasan
Ngaran produk
HWTS-RT071A 12 Rupa Pakakas Détéksi Asam Nukléat Patogén Pernapasan (PCR Fluoresensi)
Saluran
| Saluran | hu12Buffer Réaksi A | hu12Buffer Réaksi B | hu12Buffer Réaksi C | hu12Buffer Réaksi D |
| FAM | SARS-CoV-2 | HADV | HPIV Ⅰ | HRV |
| VIC/HEX | Kontrol Internal | Kontrol Internal | HPIV II | Kontrol Internal |
| CY5 | IFV A | MP | HPIV III | / |
| ROX | IFV B | RSV | HPIV Ⅳ | HMPV |
Parameter Téknis
| Panyimpenan | ≤-18℃ |
| Umur simpan | 12 bulan |
| Jenis Spésimen | Kapas orofaring |
| Ct | ≤38 |
| CV | ≤5.0% |
| LoD | SARS-CoV-2:300 Salinan/mLVirus influenza B:500 Salinan/mLVirus influenza A:500 Salinan/mL Adenovirus:500 Salinan/mL mycoplasma pneumoniae:500 Salinan/mL Virus pernapasan sinsitial:500 Salinan/mL, Virus parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 Salinan/mL Rhinovirus:500 Salinan/mL metapneumovirus manusa:500 Salinan/mL |
| Spésifikasi | Ulikan cross-réaktivitas nunjukkeun yén teu aya cross-réaktivitas antara kit ieu sareng enterovirus A, B, C, D, virus epstein-barr, virus campak, sitomegalovirus manusa, rotavirus, norovirus, virus gondok, virus varicella-herpes zoster, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans sareng asam nukléat génomik manusa. |
| Instrumen anu Lumaku | Sistem PCR Real-Time Biosystems Terapan 7500Sistem PCR Real-Time Gancang Biosystems Terapan 7500QuantStudio®5 Sistem PCR Real-Time Sistem PCR Real-Time SLAN-96P (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Sistem PCR Real-Time, Sistem Deteksi PCR Real-Time LineGene 9600 Plus(FQD-96A,téhnologi Hangzhou Bioer) MA-6000 Siklus Termal Kuantitatif Waktos Nyata (Suzhou Molarray Co., Ltd.) Sistem PCR BioRad CFX96 Real-Time Sistem PCR Real-Time BioRad CFX Opus 96 |
Aliran Padamelan
Pilihan 1.
Réagen ékstraksi anu disarankeun: Réagen Pelepasan Sampel Makro & Mikro-Test (HWTS-3005-8) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ékstraksi kedah dilaksanakeun sacara ketat saluyu sareng pitunjuk.
Pilihan 2.
Réagen ékstraksi anu disarankeun: Kit DNA/RNA Umum Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) sareng Ékstraktor Asam Nukléat Otomatis Macro & Micro-Test (HWTS-3006C, HWTS-3006B) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., ékstraksi kedah dilaksanakeun dumasar kana pitunjuk sacara ketat. Volume élusi anu disarankeun nyaéta 80μL.
Pilihan 3.
Réagen ékstraksi anu disarankeun: Kit Ékstraksi atanapi Purifikasi Asam Nukléat (YDP315) ku Tiangen Biotech (Beijing) Co., Ltd., ékstraksi kedah dilaksanakeun numutkeun pitunjuk sacara ketat. Volume élusi anu disarankeun nyaéta 100μL.







