12 Jenis Patogen Pernapasan

Pedaran Singkat:

Kit ieu dianggo pikeun deteksi kualitatif gabungan SARS-CoV-2, virus influenza A, virus influenza B, adenovirus, mycoplasma pneumoniae, rhinovirus, virus respiratory syncytial sareng virus parainfluenza (Ⅰ, II, III, IV) sareng metapneumovirus manusa dina swab oropharyngeal..


Rincian Produk

Tag Produk

Ngaran produk

HWTS-RT071A 12 Rupa Pakakas Détéksi Asam Nukléat Patogén Pernapasan (PCR Fluoresensi)

Saluran

Saluran hu12Buffer Réaksi A hu12Buffer Réaksi B hu12Buffer Réaksi C hu12Buffer Réaksi D
FAM SARS-CoV-2 HADV HPIV Ⅰ HRV
VIC/HEX Kontrol Internal Kontrol Internal HPIV II Kontrol Internal
CY5 IFV A MP HPIV III /
ROX IFV B RSV HPIV Ⅳ HMPV

Parameter Téknis

Panyimpenan

≤-18℃

Umur simpan 12 bulan
Jenis Spésimen Kapas orofaring
Ct ≤38
CV ≤5.0%
LoD SARS-CoV-2:300 Salinan/mLVirus influenza B:500 Salinan/mLVirus influenza A:500 Salinan/mL

Adenovirus:500 Salinan/mL

mycoplasma pneumoniae:500 Salinan/mL

Virus pernapasan sinsitial:500 Salinan/mL,

Virus parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 Salinan/mL

Rhinovirus:500 Salinan/mL

metapneumovirus manusa:500 Salinan/mL

Spésifikasi Ulikan cross-réaktivitas nunjukkeun yén teu aya cross-réaktivitas antara kit ieu sareng enterovirus A, B, C, D, virus epstein-barr, virus campak, sitomegalovirus manusa, rotavirus, norovirus, virus gondok, virus varicella-herpes zoster, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans sareng asam nukléat génomik manusa.
Instrumen anu Lumaku Sistem PCR Real-Time Biosystems Terapan 7500Sistem PCR Real-Time Gancang Biosystems Terapan 7500QuantStudio®5 Sistem PCR Real-Time

Sistem PCR Real-Time SLAN-96P (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Sistem PCR Real-Time,

Sistem Deteksi PCR Real-Time LineGene 9600 Plus(FQD-96A,téhnologi Hangzhou Bioer)

MA-6000 Siklus Termal Kuantitatif Waktos Nyata (Suzhou Molarray Co., Ltd.)

Sistem PCR BioRad CFX96 Real-Time

Sistem PCR Real-Time BioRad CFX Opus 96

Aliran Padamelan

Pilihan 1.

Réagen ékstraksi anu disarankeun: Réagen Pelepasan Sampel Makro & Mikro-Test (HWTS-3005-8) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Ékstraksi kedah dilaksanakeun sacara ketat saluyu sareng pitunjuk.

 Pilihan 2.

Réagen ékstraksi anu disarankeun: Kit DNA/RNA Umum Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) sareng Ékstraktor Asam Nukléat Otomatis Macro & Micro-Test (HWTS-3006C, HWTS-3006B) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., ékstraksi kedah dilaksanakeun dumasar kana pitunjuk sacara ketat. Volume élusi anu disarankeun nyaéta 80μL.

 Pilihan 3.

Réagen ékstraksi anu disarankeun: Kit Ékstraksi atanapi Purifikasi Asam Nukléat (YDP315) ku Tiangen Biotech (Beijing) Co., Ltd., ékstraksi kedah dilaksanakeun numutkeun pitunjuk sacara ketat. Volume élusi anu disarankeun nyaéta 100μL.


  • Saméméhna:
  • Teras:

  • Tulis pesen anjeun di dieu sareng kirimkeun ka kami