11 Jenis Patogén Pernafasan
Ngaran produk
HWTS-RT162A 11 Jenis Kit Deteksi Asam Nukléat Patogén Pernapasan(Fluoresensi PCR)
Saluran
靶标 | Saluran | |||
核酸反应液A | 核酸反应液B | 核酸反应液C | 核酸反应液D | |
HI | Smet | MP | Suku | FAM |
SP | PA | Bp | / | CY5 |
KPN | ABA | Bpp | Cpn | ROX |
内参 | 内参 | 内参 | 内参 | VIC/HEX |
Épidemiologi
Inféksi saluran pernapasan mangrupikeun kelas panyakit anu penting anu nyababkeun ancaman serius pikeun kaséhatan manusa, sareng panilitian nunjukkeun yén kalolobaan inféksi saluran pernapasan disababkeun ku patogén baktéri sareng atanapi virus anu ngainféksi host, ngarah kana parah parah panyakit bahkan maot, ku kituna netelakeun patogén ngamungkinkeun pikeun pengobatan anu dituju sareng ningkatkeun tingkat kasalametan pasien.[1,2].
Parameter Téknis
Panyimpenan | ≤-18 ℃ |
Kahirupan rak | 12 bulan |
Jenis spésimén | Sputum |
Ct | HI, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Leg: Ct≤38 |
CV | <5,0% |
LoD | Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia sareng Legionellapneumophila: 1000 CFU/mL; Bordetella pertussis na Bacillus parapertussis: 500 CFU / ml; Mycoplasma pneumoniae jeung Chlamydia pneumoniae: 200 éksemplar/mL. |
Spésifikasi | Hasil uji réaktivitas silang nunjukkeun yén teu aya réaksi silang antara kit ieu sareng Cytomegalovirus, virus Herpes simpléks tipe 1, virus Varicella-zoster, virus Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophilalis, galur Legionella. Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia, Corstriactum, Corstriatum, No. Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Chlamydia psittaci, Coxiella burnetii jeung inti génomik asam manusa. |
Instrumén lumaku | Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 gancang Real-Time PCR Systems QuantStudio®5 Sistem PCR Real-Time SLAN-96P Real-Time PCR Systems LightCycler®480 Sistim PCR Real-Time LineGene 9600 Ditambah Real-Time Sistim deteksi PCR MA-6000 Real-Time kuantitatif termal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time Sistim PCR |
Aliran Gawé
Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (anu tiasa dianggo sareng Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Tambahkeun 200µL tinafisiologissaline kana endapan anu diolah, sareng léngkah-léngkah saterasna kedah dilaksanakeun saluyu sareng petunjuk. Volume élusi anu disarankeun nyaéta 100 µL.