11 Jenis Patogen Pernapasan
Ngaran produk
HWTS-RT162A 11 Jenis Pakakas Détéksi Asam Nukléat Patogén Pernapasan(PCR Fluoresensi)
Saluran
| 靶标 | Saluran | |||
| 核酸反应液A | 核酸反应液B | 核酸反应液C | 核酸反应液D | |
| HI | Smet | MP | Suku | FAM |
| SP | PA | Bp | / | CY5 |
| KPN | ABA | Bpp | Cpn | ROX |
| 内参 | 内参 | 内参 | 内参 | VIC/HEX |
Epidemiologi
Infeksi saluran pernapasan mangrupikeun kelas panyakit penting anu nyababkeun ancaman serius pikeun kaséhatan manusa, sareng panilitian nunjukkeun yén kalolobaan inféksi saluran pernapasan disababkeun ku patogén baktéri sareng/atanapi virus anu ngainféksi host, anu nyababkeun ningkatna parahna panyakit sareng bahkan maot, janten ngajelaskeun patogén ngamungkinkeun perawatan anu ditujukeun sareng ningkatkeun tingkat kasalametan pasien.[1,2].
Parameter Téknis
| Panyimpenan | ≤-18℃ |
| Umur simpan | 12 bulan |
| Jenis Spésimen | Dahak |
| Ct | HI, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Suku: Ct≤38 |
| CV | <5.0% |
| LoD | Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia sareng Legionellapneumophila: 1000 CFU/mL; Bordetella pertussis sareng Bacillus parapertussis: 500 CFU/mL; Mycoplasma pneumoniae sareng Chlamydia pneumoniae: 200 kopi/mL. |
| Spésifikasi | Hasil uji cross-reactivity nunjukkeun yén teu aya cross reaction antara kit ieu sareng Cytomegalovirus, Herpes simplex virus type 1, Varicella-zoster virus, Epstein-Barr virus, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophila, Moraxella catarrhalis, attenuated strains of Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Chlamydia psittaci, Coxiella burnetii sareng asam nukléat génomik manusa. |
| Instrumen anu Lumaku | Sistem PCR Real-Time Biosystems Terapan 7500 Sistem PCR Real-Time Gancang Biosystems Terapan 7500 QuantStudio®5 Sistem PCR Real-Time Sistem PCR Real-Time SLAN-96P LightCycler®480 Sistem PCR Real-Time Sistem Deteksi PCR Real-Time LineGene 9600 Plus Siklus Termal Kuantitatif Waktos Nyata MA-6000 Sistem PCR BioRad CFX96 Real-Time Sistem PCR Real-Time BioRad CFX Opus 96 |
Aliran Padamelan
Kit DNA/RNA Umum Makro & Mikro-Test (HWTS-3019) (anu tiasa dianggo sareng Ékstraktor Asam Nukléat Otomatis Makro & Mikro-Test (HWTS-3006C, HWTS-3006B)) ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Tambahkeun 200µL tinafisiologissaline kana endapan anu diolah, sareng léngkah-léngkah salajengna kedah dilaksanakeun saluyu sareng pitunjuk. Volume elusi anu disarankeun nyaéta 100 µL.